<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>144 Fibers Series &#8211; www.philisun.com</title>
	<atom:link href="https://www.philisun.com/product/mpo-trunk-cable-series/144-fibers-series/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.philisun.com</link>
	<description>Optical transceivers support &#60;strong&#62;10G to 800G&#60;/strong&#62; high-speed transmission</description>
	<lastBuildDate>Wed, 21 Jan 2026 06:36:47 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.philisun.com/wp-content/uploads/2025/10/philisun斐立飒-logo彩色方形-1-100x100.png</url>
	<title>144 Fibers Series &#8211; www.philisun.com</title>
	<link>https://www.philisun.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>MPO-144 Trunk Cable &#8211; 144 Fiber Main Trunk Cord, Base-24, Supports OS2/OM3/OM4/OM5, for Maximum Density Backbone, PC/APC Polish (Female/Male), Type A/B/C/D/E</title>
		<link>https://www.philisun.com/products/mpo-144-fibers-base-24-trunk-cable/</link>
		
		<dc:creator><![CDATA[philisun001]]></dc:creator>
		<pubDate>Tue, 13 Jan 2026 05:40:42 +0000</pubDate>
				<guid isPermaLink="false">https://www.philisun.com/?post_type=product&#038;p=4683</guid>

					<description><![CDATA[<p>Applicable to multiple applications based on MPO 4-channel or 6-channel dual-fiber bidirectional transmission<br />
Applicable to multiple applications based on MPO 12-channel single-fiber bidirectional transmission<br />
Optical transceiver interconnection</p>
<p><a rel="nofollow" href="https://www.philisun.com/products/mpo-144-fibers-base-24-trunk-cable/">MPO-144 Trunk Cable &#8211; 144 Fiber Main Trunk Cord, Base-24, Supports OS2/OM3/OM4/OM5, for Maximum Density Backbone, PC/APC Polish (Female/Male), Type A/B/C/D/E</a>最先出现在<a rel="nofollow" href="https://www.philisun.com">www.philisun.com</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div class="tablepress-wrapper">
<table id="tablepress-179" class="tablepress tablepress-id-179">
<thead>
<tr class="row-1">
	<th colspan="4" class="column-1">SPECIFICATIONS</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2">
	<td class="column-1"><strong>Connector A</strong></td><td class="column-2">MPO</td><td class="column-3"><strong>Connector B</strong></td><td class="column-4">MPO</td>
</tr>
<tr class="row-3">
	<td class="column-1"><strong>Fiber type</strong></td><td class="column-2">SM OS2/OM3/OM4/OM5</td><td class="column-3"><strong>Fiber number</strong></td><td class="column-4">144Fibers（Base-24）</td>
</tr>
<tr class="row-4">
	<td class="column-1"><strong>MPO IL</strong></td><td class="column-2">Standard loss/low loss</td><td class="column-3"><strong>Polishing</strong></td><td class="column-4">PC or APC</td>
</tr>
<tr class="row-5">
	<td class="column-1"><strong>Cable structure</strong></td><td class="column-2">Double Jacket</td><td class="column-3"><strong>Connector boot type</strong></td><td class="column-4">Round fiber</td>
</tr>
<tr class="row-6">
	<td class="column-1"><strong>Connctor type</strong></td><td class="column-2">Female/Male</td><td class="column-3"><strong>RL</strong></td><td class="column-4">≥60dB(SM)    ≥20dB(MM)</td>
</tr>
<tr class="row-7">
	<td class="column-1"><strong>IL(Typical)</strong></td><td class="column-2">0.1/0.2dB</td><td class="column-3"><strong>IL(Max. value)</strong></td><td class="column-4">0.35/0.6dB</td>
</tr>
<tr class="row-8">
	<td class="column-1"><strong>Breakout outside diameter (OD)</strong></td><td class="column-2">2.0/3.0mm</td><td class="column-3"><strong>Cable color</strong></td><td class="column-4">Yellow/Aque/Violet/Lime green</td>
</tr>
<tr class="row-9">
	<td class="column-1"><strong>Breakout length</strong></td><td class="column-2">0.3-1.5m</td><td class="column-3"><strong>Flame retardant grade</strong></td><td class="column-4">OFN/OFNR/OFNP</td>
</tr>
<tr class="row-10">
	<td class="column-1"><strong>Cable material</strong></td><td class="column-2">LSZH/PVC/TPU</td><td class="column-3"><strong>Fiber loss</strong></td><td class="column-4">SM:0.35db@1310nm/0.2dB@1550nm  MM:2.4dB@850nm/0.6dB@1300nm   </td>
</tr>
<tr class="row-11">
	<td class="column-1"><strong>Fiber brand</strong></td><td class="column-2">Corning/YOFC</td><td class="column-3"><strong>Min.bending radius(long term)</strong></td><td class="column-4">20D</td>
</tr>
<tr class="row-12">
	<td class="column-1"><strong>Working wavelength</strong></td><td class="column-2">1310/1550(SM)     850/1300(MM)</td><td class="column-3"><strong>Durability</strong></td><td class="column-4">≥500 times</td>
</tr>
<tr class="row-13">
	<td class="column-1"><strong>Min.bending radius(short term)</strong></td><td class="column-2">10D</td><td class="column-3"><strong>Polarity</strong></td><td class="column-4">TYPE A/B/C/D/E</td>
</tr>
<tr class="row-14">
	<td class="column-1"><strong>Operating temperature</strong></td><td class="column-2">-10 to 70℃ (14 to 158℉)</td><td class="column-3"><strong>Storage temperature</strong></td><td class="column-4">-40 to 85℃ (-40 to 185℉)</td>
</tr>
</tbody>
</table>
<!-- #tablepress-179 from cache --></div>
<div></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">PRODUCT PRESENTATION</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div>This 144-Fiber Base-24 MPO Trunk Cable is strictly applicable to multiple applications based on MPO 4-channel or 6-channel dual-fiber bidirectional transmission, multiple applications based on MPO 12-channel single-fiber bidirectional transmission, and Optical transceiver interconnection. Constructed with 144 Fibers of SM OS2/OM3/OM4/OM5 (Corning/YOFC brand). MPO connectors (Female/Male) with PC or APC polish guarantee RL ≥60dB (SM) / ≥20dB (MM). The low-loss option ensures IL Max. ≤0.35dB (Typical 0.1/0.2dB). The cable uses a Double Jacket structure with LSZH/PVC/TPU material, supports TYPE A/B/C polarity, and has ≥500 times durability.</div>
<div></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">MPO TRUNK CABLE SERIES PRODUCTS</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div><img fetchpriority="high" decoding="async" class="aligncenter wp-image-4251 size-full" src="https://www.philisun.com/wp-content/uploads/2026/01/MPO-Trunks-6xBase-12-SERIES-PRODUCTS.jpg" alt="" width="1171" height="263" srcset="https://www.philisun.com/wp-content/uploads/2026/01/MPO-Trunks-6xBase-12-SERIES-PRODUCTS.jpg 1171w, https://www.philisun.com/wp-content/uploads/2026/01/MPO-Trunks-6xBase-12-SERIES-PRODUCTS-300x67.jpg 300w, https://www.philisun.com/wp-content/uploads/2026/01/MPO-Trunks-6xBase-12-SERIES-PRODUCTS-1024x230.jpg 1024w, https://www.philisun.com/wp-content/uploads/2026/01/MPO-Trunks-6xBase-12-SERIES-PRODUCTS-768x172.jpg 768w, https://www.philisun.com/wp-content/uploads/2026/01/MPO-Trunks-6xBase-12-SERIES-PRODUCTS-500x112.jpg 500w, https://www.philisun.com/wp-content/uploads/2026/01/MPO-Trunks-6xBase-12-SERIES-PRODUCTS-600x135.jpg 600w" sizes="(max-width: 1171px) 100vw, 1171px" /></div>
<div></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">Production &amp; Testing Equipment</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div><img decoding="async" class="aligncenter size-full wp-image-2078" src="https://www.philisun.com/wp-content/uploads/2025/09/5跳线生产及检测环境.jpg" alt="" width="1500" height="500" srcset="https://www.philisun.com/wp-content/uploads/2025/09/5跳线生产及检测环境.jpg 1500w, https://www.philisun.com/wp-content/uploads/2025/09/5跳线生产及检测环境-300x100.jpg 300w, https://www.philisun.com/wp-content/uploads/2025/09/5跳线生产及检测环境-1024x341.jpg 1024w, https://www.philisun.com/wp-content/uploads/2025/09/5跳线生产及检测环境-768x256.jpg 768w, https://www.philisun.com/wp-content/uploads/2025/09/5跳线生产及检测环境-500x167.jpg 500w, https://www.philisun.com/wp-content/uploads/2025/09/5跳线生产及检测环境-600x200.jpg 600w" sizes="(max-width: 1500px) 100vw, 1500px" /></div>
<div></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">FIBER OPTIC CABLE STRUCTURE</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div><img decoding="async" class="aligncenter wp-image-4252 size-full" src="https://www.philisun.com/wp-content/uploads/2026/01/光缆结构图-MPO-Trunks-6xBase-12.jpg" alt="" width="1300" height="336" srcset="https://www.philisun.com/wp-content/uploads/2026/01/光缆结构图-MPO-Trunks-6xBase-12.jpg 1300w, https://www.philisun.com/wp-content/uploads/2026/01/光缆结构图-MPO-Trunks-6xBase-12-300x78.jpg 300w, https://www.philisun.com/wp-content/uploads/2026/01/光缆结构图-MPO-Trunks-6xBase-12-1024x265.jpg 1024w, https://www.philisun.com/wp-content/uploads/2026/01/光缆结构图-MPO-Trunks-6xBase-12-768x198.jpg 768w, https://www.philisun.com/wp-content/uploads/2026/01/光缆结构图-MPO-Trunks-6xBase-12-500x129.jpg 500w, https://www.philisun.com/wp-content/uploads/2026/01/光缆结构图-MPO-Trunks-6xBase-12-600x155.jpg 600w" sizes="(max-width: 1300px) 100vw, 1300px" /></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">PERFORMANCE PARAMETER</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div class="tablepress-wrapper">
<table id="tablepress-8" class="tablepress tablepress-id-8 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="4" class="column-1">Technical Performance</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2">
	<td rowspan="2" class="column-1">Ferrule type</td><td colspan="2" class="column-2">Insertion loss</td><td rowspan="2" class="column-4">Return loss</td>
</tr>
<tr class="row-3">
	<td class="column-2">Typical</td><td class="column-3">Maximum</td>
</tr>
<tr class="row-4">
	<td class="column-1">SM standard loss</td><td class="column-2">0.20dB</td><td class="column-3">≤0.75dB</td><td rowspan="2" class="column-4">≥ 60dB （APC 8°）</td>
</tr>
<tr class="row-5">
	<td class="column-1">SM low loss</td><td class="column-2">0.10dB</td><td class="column-3">≤0.35dB</td>
</tr>
<tr class="row-6">
	<td class="column-1">MM standard loss</td><td class="column-2">0.20dB</td><td class="column-3">≤0.6dB</td><td rowspan="2" class="column-4">≥ 20dB</td>
</tr>
<tr class="row-7">
	<td class="column-1">MM low loss</td><td class="column-2">0.10dB</td><td class="column-3">≤0.35dB</td>
</tr>
</tbody>
</table>
<!-- #tablepress-8 from cache --></div>
<div></div>
<div class="tablepress-wrapper">
<table id="tablepress-9" class="tablepress tablepress-id-9 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="7" class="column-1">MT Ferrule Options</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2">
	<td colspan="2" class="column-1">Fiber mode</td><td colspan="2" class="column-3">Performance</td><td colspan="3" class="column-5">Fiber count</td>
</tr>
<tr class="row-3">
	<td colspan="2" rowspan="3" class="column-1">Single mode</td><td colspan="2" rowspan="2" class="column-3">Standard loss</td><td colspan="3" class="column-5">12 (1x12)</td>
</tr>
<tr class="row-4">
	<td colspan="3" class="column-5">24 (2x12)</td>
</tr>
<tr class="row-5">
	<td colspan="2" class="column-3">Low loss</td><td colspan="3" class="column-5">12 (1x12)</td>
</tr>
<tr class="row-6">
	<td colspan="2" rowspan="6" class="column-1">Multimode</td><td colspan="2" rowspan="4" class="column-3">Standard loss</td><td colspan="3" class="column-5">12 (1x12)</td>
</tr>
<tr class="row-7">
	<td colspan="3" class="column-5">16 (1x16)</td>
</tr>
<tr class="row-8">
	<td colspan="3" class="column-5">24 (2x12)</td>
</tr>
<tr class="row-9">
	<td colspan="3" class="column-5">32 (2x16)</td>
</tr>
<tr class="row-10">
	<td colspan="2" rowspan="2" class="column-3">Low loss</td><td colspan="3" class="column-5">12 (1x12)</td>
</tr>
<tr class="row-11">
	<td colspan="3" class="column-5">24 (2x12)</td>
</tr>
</tbody>
</table>
<!-- #tablepress-9 from cache --></div>
<div></div>
<div class="tablepress-wrapper">
<table id="tablepress-125" class="tablepress tablepress-id-125 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="9" class="column-1">Cable Parameter</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2">
	<td colspan="2" class="column-1">Items</td><td colspan="7" class="column-3">Specifications</td>
</tr>
<tr class="row-3">
	<td colspan="2" class="column-1"> Fiber Count</td><td class="column-3">24</td><td class="column-4">32</td><td class="column-5">36</td><td class="column-6">48</td><td class="column-7">72</td><td class="column-8">96</td><td class="column-9">144</td>
</tr>
<tr class="row-4">
	<td colspan="2" class="column-1">Unit Count</td><td class="column-3">2 or 3</td><td class="column-4">2 or 4</td><td class="column-5">3</td><td class="column-6">4 or 6</td><td class="column-7">6</td><td class="column-8">8 or 12</td><td class="column-9">12 or 24</td>
</tr>
<tr class="row-5">
	<td colspan="2" class="column-1">Fillers</td><td class="column-3">2</td><td colspan="6" class="column-4">0</td>
</tr>
<tr class="row-6">
	<td rowspan="2" class="column-1">Fiber</td><td class="column-2">Diameter</td><td colspan="7" class="column-3">250±15μm</td>
</tr>
<tr class="row-7">
	<td class="column-2">Color</td><td colspan="7" class="column-3">Blue/Orange/Green/Brown/Gray/White/Red/Black/Yellow/Purple/Pink/Aqua</td>
</tr>
<tr class="row-8">
	<td rowspan="6" class="column-1">Subunit</td><td class="column-2"> Fiber Count</td><td colspan="7" class="column-3">12</td>
</tr>
<tr class="row-9">
	<td class="column-2">Diameter</td><td colspan="7" class="column-3">2.9±0.1mm</td>
</tr>
<tr class="row-10">
	<td class="column-2">Material</td><td colspan="7" class="column-3">PVC /LSZH</td>
</tr>
<tr class="row-11">
	<td class="column-2">Color<sup>1</sup></td><td colspan="7" class="column-3">Blue/Orange/Green/Brown/Gray/White/Red/Black/Yellow/Purple/Pink/Aqua</td>
</tr>
<tr class="row-12">
	<td class="column-2">Strength Member</td><td colspan="7" class="column-3">Aramid Yarn</td>
</tr>
<tr class="row-13">
	<td class="column-2">Marks<sup>1</sup></td><td colspan="7" class="column-3">1# - 12#</td>
</tr>
<tr class="row-14">
	<td colspan="2" class="column-1">Central Strength Member<sup>2</sup></td><td colspan="4" class="column-3">-</td><td colspan="3" class="column-7">FRP +(PVC / LSZH)</td>
</tr>
<tr class="row-15">
	<td rowspan="3" class="column-1">  Outer Jacket</td><td class="column-2">Diameter</td><td colspan="4" class="column-3">9.5±0.5mm</td><td class="column-7">11.5±0.5mm</td><td class="column-8">13.5±0.5mm</td><td class="column-9">17.0±0.5mm</td>
</tr>
<tr class="row-16">
	<td class="column-2">Material</td><td colspan="7" class="column-3">PVC /LSZH</td>
</tr>
<tr class="row-17">
	<td class="column-2">Color</td><td colspan="7" class="column-3">Blue/Orange/Green/Brown/Gray/White/Red/Black/Yellow/Purple/Pink/Aqua</td>
</tr>
<tr class="row-18">
	<td colspan="9" rowspan="3" class="column-1">Note 1: Each subunit is usually distinguished by different jacket colors, number marks only for optional.<br />
Note 2: The central strength member is optional for 48FO mini cable.<br />
Note 3: The fiber count in each subunit can be customized, equal or unequal.</td>
</tr>
<tr class="row-19">
	
</tr>
<tr class="row-20">
	
</tr>
</tbody>
</table>
<!-- #tablepress-125 from cache --></div>
<div></div>
<div class="tablepress-wrapper">
<table id="tablepress-126" class="tablepress tablepress-id-126 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="8" class="column-1">Mechanical Performance</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2">
	<td class="column-1">Items</td><td colspan="7" class="column-2">Specifications</td>
</tr>
<tr class="row-3">
	<td class="column-1">Fiber Count</td><td class="column-2">24</td><td class="column-3">32</td><td class="column-4">36</td><td class="column-5">48</td><td class="column-6">72</td><td class="column-7">96</td><td class="column-8">144</td>
</tr>
<tr class="row-4">
	<td class="column-1">Subunit Count</td><td class="column-2">2 or 3</td><td class="column-3">2 or 4</td><td class="column-4">3</td><td class="column-5">4 or 6</td><td class="column-6">6</td><td class="column-7">8 or 12</td><td class="column-8">12 or 24</td>
</tr>
<tr class="row-5">
	<td class="column-1">Tensile Strength (Long Term) / N</td><td colspan="3" class="column-2">300</td><td class="column-5">200</td><td colspan="3" class="column-6">400</td>
</tr>
<tr class="row-6">
	<td class="column-1">Tensile Strength (Short Term)/ N</td><td colspan="3" class="column-2">600</td><td class="column-5">400</td><td colspan="3" class="column-6">1000</td>
</tr>
<tr class="row-7">
	<td class="column-1">Crush Resistance<br />
 (Long Term) / N/10cm</td><td colspan="7" class="column-2">300</td>
</tr>
<tr class="row-8">
	<td class="column-1">Crush Resistance<br />
 (Long Term) / N/10cm</td><td colspan="7" class="column-2">1000</td>
</tr>
<tr class="row-9">
	<td class="column-1"> Min. Bend Radius (Dynamic) / mm</td><td colspan="7" class="column-2">20D</td>
</tr>
<tr class="row-10">
	<td class="column-1">Min. Bend Radius (Static)/ mm</td><td colspan="7" class="column-2">10D</td>
</tr>
<tr class="row-11">
	<td class="column-1">Operating Temperature/℃</td><td colspan="7" class="column-2">-20～+60</td>
</tr>
<tr class="row-12">
	<td class="column-1">Storage Temperature/℃</td><td colspan="7" class="column-2">-20～+60</td>
</tr>
</tbody>
</table>
<!-- #tablepress-126 from cache --></div>
<div></div>
<div class="tablepress-wrapper">
<table id="tablepress-7" class="tablepress tablepress-id-7 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="9" class="column-1">SM Fiber Parameter</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2">
	<td colspan="5" class="column-1">Items</td><td class="column-6">Unit</td><td class="column-7">G.652D</td><td class="column-8">G.657A1</td><td class="column-9">G.657A2</td>
</tr>
<tr class="row-3">
	<td colspan="3" rowspan="2" class="column-1">Mode Field Diameter</td><td colspan="2" class="column-4">1310nm</td><td class="column-6">μm</td><td class="column-7">9.1±0.4</td><td class="column-8">8.8±0.4</td><td class="column-9">8.8±0.4</td>
</tr>
<tr class="row-4">
	<td colspan="2" class="column-4">1550nm</td><td class="column-6">μm</td><td class="column-7">10.4±0.5</td><td class="column-8">9.8±0.5</td><td class="column-9">9.8±0.5</td>
</tr>
<tr class="row-5">
	<td colspan="5" class="column-1">Cladding Diameter</td><td class="column-6">μm</td><td class="column-7">125±1</td><td class="column-8">125±0.7</td><td class="column-9">125±0.7</td>
</tr>
<tr class="row-6">
	<td colspan="5" class="column-1">Cladding Non-Circularity</td><td class="column-6">%</td><td class="column-7">≤1</td><td class="column-8">≤0.7</td><td class="column-9">≤0.7</td>
</tr>
<tr class="row-7">
	<td colspan="5" class="column-1">Core-Cladding Concentricity Error</td><td class="column-6">μm</td><td class="column-7">≤0.6</td><td class="column-8">≤0.5</td><td class="column-9">≤0.5</td>
</tr>
<tr class="row-8">
	<td colspan="5" class="column-1">Coating Diameter</td><td class="column-6">μm</td><td class="column-7">245±7</td><td class="column-8">245±5</td><td class="column-9">245±5</td>
</tr>
<tr class="row-9">
	<td colspan="5" class="column-1">Coating Non-Circularity</td><td class="column-6">%</td><td class="column-7">≤6.0</td><td class="column-8">≤6.0</td><td class="column-9">≤6.0</td>
</tr>
<tr class="row-10">
	<td colspan="5" class="column-1">Cladding-Coating Concentricity Error</td><td class="column-6">μm</td><td class="column-7">≤12.0</td><td class="column-8">≤12.0</td><td class="column-9">≤12.0</td>
</tr>
<tr class="row-11">
	<td colspan="5" class="column-1">Cable Cutoff Wavelength</td><td class="column-6">nm</td><td class="column-7">λcc≤1260</td><td class="column-8">λcc≤1260</td><td class="column-9">λcc≤1260</td>
</tr>
<tr class="row-12">
	<td colspan="3" rowspan="2" class="column-1">Cable Attenuation Coefficient</td><td colspan="2" class="column-4">1310nm</td><td class="column-6">dB/km</td><td class="column-7">≤0.4</td><td class="column-8">≤0.4</td><td class="column-9">≤0.4</td>
</tr>
<tr class="row-13">
	<td colspan="2" class="column-4">1550nm</td><td class="column-6">dB/km</td><td class="column-7">≤0.3</td><td class="column-8">≤0.3</td><td class="column-9">≤0.3</td>
</tr>
</tbody>
</table>
<!-- #tablepress-7 from cache --></div>
<div></div>
<div class="tablepress-wrapper">
<table id="tablepress-19" class="tablepress tablepress-id-19 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="9" class="column-1">MM Fiber Parameter</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2">
	<td colspan="3" class="column-1">Items</td><td class="column-4">unit</td><td class="column-5">62.5/125</td><td class="column-6">50/125</td><td class="column-7">OM3-150</td><td class="column-8">OM3-300</td><td class="column-9">OM4</td>
</tr>
<tr class="row-3">
	<td colspan="3" class="column-1">Core Diameter</td><td class="column-4">μm</td><td class="column-5">62.5±2.5</td><td class="column-6">50±2.5</td><td class="column-7">50±2.5</td><td class="column-8">50±2.5</td><td class="column-9">50±2.5</td>
</tr>
<tr class="row-4">
	<td colspan="3" class="column-1">Cladding Diameter</td><td class="column-4">μm</td><td class="column-5">125±1.0</td><td class="column-6">125±1.0</td><td class="column-7">125±1.0</td><td class="column-8">125±1.0</td><td class="column-9">125±1.0</td>
</tr>
<tr class="row-5">
	<td colspan="3" class="column-1">Core Non-Circularity</td><td class="column-4">%</td><td class="column-5">≤5.0</td><td class="column-6">≤5.0</td><td class="column-7">≤5.0</td><td class="column-8">≤5.0</td><td class="column-9">≤5.0</td>
</tr>
<tr class="row-6">
	<td colspan="3" class="column-1">Cladding Non-Circularity</td><td class="column-4">%</td><td class="column-5">≤1.0</td><td class="column-6">≤1.0</td><td class="column-7">≤1.0</td><td class="column-8">≤1.0</td><td class="column-9">≤1.0</td>
</tr>
<tr class="row-7">
	<td colspan="3" class="column-1">Core-Cladding Concentricity Error</td><td class="column-4">μm</td><td class="column-5">≤1.5</td><td class="column-6">≤1.5</td><td class="column-7">≤1.0</td><td class="column-8">≤1.0</td><td class="column-9">≤1.0</td>
</tr>
<tr class="row-8">
	<td colspan="3" class="column-1">Coating Diameter</td><td class="column-4">μm</td><td class="column-5">245±7</td><td class="column-6">245±7</td><td class="column-7">245±7</td><td class="column-8">245±7</td><td class="column-9">245±7</td>
</tr>
<tr class="row-9">
	<td colspan="3" class="column-1">Coating Non-Circularity</td><td class="column-4">%</td><td class="column-5">≤6.0</td><td class="column-6">≤6.0</td><td class="column-7">≤6.0</td><td class="column-8">≤6.0</td><td class="column-9">≤6.0</td>
</tr>
<tr class="row-10">
	<td colspan="3" class="column-1">Cladding-Coating Concentricity Error</td><td class="column-4">μm</td><td class="column-5">≤12.0</td><td class="column-6">≤12.0</td><td class="column-7">≤12.0</td><td class="column-8">≤12.0</td><td class="column-9">≤12.0</td>
</tr>
<tr class="row-11">
	<td colspan="2" rowspan="2" class="column-1">OFL Bandwidth</td><td class="column-3">850nm</td><td class="column-4">MHz·km</td><td class="column-5">≥160</td><td class="column-6">≥500</td><td class="column-7">≥700</td><td class="column-8">≥1500</td><td class="column-9">≥3500</td>
</tr>
<tr class="row-12">
	<td class="column-3">1300nm</td><td class="column-4">MHz·km</td><td class="column-5">≥500</td><td class="column-6">≥500</td><td class="column-7">≥500</td><td class="column-8">≥500</td><td class="column-9">≥500</td>
</tr>
<tr class="row-13">
	<td colspan="2" rowspan="2" class="column-1">Cable Attenuation Coefficient</td><td class="column-3">850nm</td><td class="column-4">dB/km</td><td class="column-5">≤3.0</td><td class="column-6">≤3.0</td><td class="column-7">≤3.0</td><td class="column-8">≤3.0</td><td class="column-9">≤3.0</td>
</tr>
<tr class="row-14">
	<td class="column-3">1300nm</td><td class="column-4">dB/km</td><td class="column-5">≤1.0</td><td class="column-6">≤1.0</td><td class="column-7">≤1.0</td><td class="column-8">≤1.0</td><td class="column-9">≤1.0</td>
</tr>
</tbody>
</table>
<!-- #tablepress-19 from cache --></div>
<div></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">Product Certification</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-2079" src="https://www.philisun.com/wp-content/uploads/2025/09/认证模块-跳线.jpg" alt="" width="1240" height="326" srcset="https://www.philisun.com/wp-content/uploads/2025/09/认证模块-跳线.jpg 1240w, https://www.philisun.com/wp-content/uploads/2025/09/认证模块-跳线-300x79.jpg 300w, https://www.philisun.com/wp-content/uploads/2025/09/认证模块-跳线-1024x269.jpg 1024w, https://www.philisun.com/wp-content/uploads/2025/09/认证模块-跳线-768x202.jpg 768w, https://www.philisun.com/wp-content/uploads/2025/09/认证模块-跳线-500x131.jpg 500w, https://www.philisun.com/wp-content/uploads/2025/09/认证模块-跳线-600x158.jpg 600w" sizes="auto, (max-width: 1240px) 100vw, 1240px" /></div>
<div></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">Quality Advantage</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-2080" src="https://www.philisun.com/wp-content/uploads/2025/09/品质对比-跳线.jpg" alt="" width="1350" height="1300" srcset="https://www.philisun.com/wp-content/uploads/2025/09/品质对比-跳线.jpg 1350w, https://www.philisun.com/wp-content/uploads/2025/09/品质对比-跳线-300x289.jpg 300w, https://www.philisun.com/wp-content/uploads/2025/09/品质对比-跳线-1024x986.jpg 1024w, https://www.philisun.com/wp-content/uploads/2025/09/品质对比-跳线-768x740.jpg 768w, https://www.philisun.com/wp-content/uploads/2025/09/品质对比-跳线-500x481.jpg 500w, https://www.philisun.com/wp-content/uploads/2025/09/品质对比-跳线-600x578.jpg 600w" sizes="auto, (max-width: 1350px) 100vw, 1350px" /></div>
<div></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">CONFIGURATION INFORMATION</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div>The form can be filled in the actual <a href="https://www.philisun.com/products/mpo-144-fibers-base-24-trunk-cable/">website url</a>.</div>
<div></div>
<div></div>
<div></div>
<div></div>
<p><a rel="nofollow" href="https://www.philisun.com/products/mpo-144-fibers-base-24-trunk-cable/">MPO-144 Trunk Cable &#8211; 144 Fiber Main Trunk Cord, Base-24, Supports OS2/OM3/OM4/OM5, for Maximum Density Backbone, PC/APC Polish (Female/Male), Type A/B/C/D/E</a>最先出现在<a rel="nofollow" href="https://www.philisun.com">www.philisun.com</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MPO-144 Trunk Cable &#8211; 144 Fiber Main Trunk Cord, Base-12, Supports OS2/OM3/OM4/OM5, for Maximum Density Backbone, PC/APC Polish (Female/Male), Type A/B/C</title>
		<link>https://www.philisun.com/products/mpo-144-fibers-base-12-trunk-cable/</link>
		
		<dc:creator><![CDATA[philisun001]]></dc:creator>
		<pubDate>Tue, 13 Jan 2026 05:25:12 +0000</pubDate>
				<guid isPermaLink="false">https://www.philisun.com/?post_type=product&#038;p=4678</guid>

					<description><![CDATA[<p>Applicable to multiple applications based on MPO 4-channel or 6-channel dual-fiber bidirectional transmission<br />
Applicable to multiple applications based on MPO 12-channel single-fiber bidirectional transmission<br />
Optical transceiver interconnection</p>
<p><a rel="nofollow" href="https://www.philisun.com/products/mpo-144-fibers-base-12-trunk-cable/">MPO-144 Trunk Cable &#8211; 144 Fiber Main Trunk Cord, Base-12, Supports OS2/OM3/OM4/OM5, for Maximum Density Backbone, PC/APC Polish (Female/Male), Type A/B/C</a>最先出现在<a rel="nofollow" href="https://www.philisun.com">www.philisun.com</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div class="tablepress-wrapper">
<table id="tablepress-178" class="tablepress tablepress-id-178">
<thead>
<tr class="row-1">
	<th colspan="4" class="column-1">SPECIFICATIONS</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2">
	<td class="column-1"><strong>Connector A</strong></td><td class="column-2">MPO</td><td class="column-3"><strong>Connector B</strong></td><td class="column-4">MPO</td>
</tr>
<tr class="row-3">
	<td class="column-1"><strong>Fiber type</strong></td><td class="column-2">SM OS2/OM3/OM4/OM5</td><td class="column-3"><strong>Fiber number</strong></td><td class="column-4">144Fibers（Base-12）</td>
</tr>
<tr class="row-4">
	<td class="column-1"><strong>MPO IL</strong></td><td class="column-2">Standard loss/low loss</td><td class="column-3"><strong>Polishing</strong></td><td class="column-4">PC or APC</td>
</tr>
<tr class="row-5">
	<td class="column-1"><strong>Cable structure</strong></td><td class="column-2">Double Jacket</td><td class="column-3"><strong>Connector boot type</strong></td><td class="column-4">Round fiber</td>
</tr>
<tr class="row-6">
	<td class="column-1"><strong>Connctor type</strong></td><td class="column-2">Female/Male</td><td class="column-3"><strong>RL</strong></td><td class="column-4">≥60dB(SM)    ≥20dB(MM)</td>
</tr>
<tr class="row-7">
	<td class="column-1"><strong>IL(Typical)</strong></td><td class="column-2">0.1/0.2dB</td><td class="column-3"><strong>IL(Max. value)</strong></td><td class="column-4">0.35/0.6dB</td>
</tr>
<tr class="row-8">
	<td class="column-1"><strong>Breakout outside diameter (OD)</strong></td><td class="column-2">2.0/3.0mm</td><td class="column-3"><strong>Cable color</strong></td><td class="column-4">Yellow/Aque/Violet/Lime green</td>
</tr>
<tr class="row-9">
	<td class="column-1"><strong>Breakout length</strong></td><td class="column-2">0.3-1.5m</td><td class="column-3"><strong>Flame retardant grade</strong></td><td class="column-4">OFN/OFNR/OFNP</td>
</tr>
<tr class="row-10">
	<td class="column-1"><strong>Cable material</strong></td><td class="column-2">LSZH/PVC/TPU</td><td class="column-3"><strong>Fiber loss</strong></td><td class="column-4">SM:0.35db@1310nm/0.2dB@1550nm  MM:2.4dB@850nm/0.6dB@1300nm   </td>
</tr>
<tr class="row-11">
	<td class="column-1"><strong>Fiber brand</strong></td><td class="column-2">Corning/YOFC</td><td class="column-3"><strong>Min.bending radius(long term)</strong></td><td class="column-4">20D</td>
</tr>
<tr class="row-12">
	<td class="column-1"><strong>Working wavelength</strong></td><td class="column-2">1310/1550(SM)     850/1300(MM)</td><td class="column-3"><strong>Durability</strong></td><td class="column-4">≥500 times</td>
</tr>
<tr class="row-13">
	<td class="column-1"><strong>Min.bending radius(short term)</strong></td><td class="column-2">10D</td><td class="column-3"><strong>Polarity</strong></td><td class="column-4">TYPE A/B/C</td>
</tr>
<tr class="row-14">
	<td class="column-1"><strong>Operating temperature</strong></td><td class="column-2">-10 to 70℃ (14 to 158℉)</td><td class="column-3"><strong>Storage temperature</strong></td><td class="column-4">-40 to 85℃ (-40 to 185℉)</td>
</tr>
</tbody>
</table>
<!-- #tablepress-178 from cache --></div>
<div></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">PRODUCT PRESENTATION</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div>This 144-Fiber Base-12 MPO Trunk Cable is strictly applicable to multiple applications based on MPO 4-channel or 6-channel dual-fiber bidirectional transmission, multiple applications based on MPO 12-channel single-fiber bidirectional transmission, and Optical transceiver interconnection. Constructed with 144 Fibers of SM OS2/OM3/OM4/OM5 (Corning/YOFC brand). MPO connectors (Female/Male) with PC or APC polish guarantee RL ≥60dB (SM) / ≥20dB (MM). The low-loss option ensures IL Max. ≤0.35dB (Typical 0.1/0.2dB). The cable uses a Double Jacket structure with LSZH/PVC/TPU material, supports TYPE A/B/C polarity, and has ≥500 times durability.</div>
<div></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">MPO TRUNK CABLE SERIES PRODUCTS</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div><img loading="lazy" decoding="async" class="aligncenter wp-image-4251 size-full" src="https://www.philisun.com/wp-content/uploads/2026/01/MPO-Trunks-6xBase-12-SERIES-PRODUCTS.jpg" alt="" width="1171" height="263" srcset="https://www.philisun.com/wp-content/uploads/2026/01/MPO-Trunks-6xBase-12-SERIES-PRODUCTS.jpg 1171w, https://www.philisun.com/wp-content/uploads/2026/01/MPO-Trunks-6xBase-12-SERIES-PRODUCTS-300x67.jpg 300w, https://www.philisun.com/wp-content/uploads/2026/01/MPO-Trunks-6xBase-12-SERIES-PRODUCTS-1024x230.jpg 1024w, https://www.philisun.com/wp-content/uploads/2026/01/MPO-Trunks-6xBase-12-SERIES-PRODUCTS-768x172.jpg 768w, https://www.philisun.com/wp-content/uploads/2026/01/MPO-Trunks-6xBase-12-SERIES-PRODUCTS-500x112.jpg 500w, https://www.philisun.com/wp-content/uploads/2026/01/MPO-Trunks-6xBase-12-SERIES-PRODUCTS-600x135.jpg 600w" sizes="auto, (max-width: 1171px) 100vw, 1171px" /></div>
<div></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">Production &amp; Testing Equipment</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-2078" src="https://www.philisun.com/wp-content/uploads/2025/09/5跳线生产及检测环境.jpg" alt="" width="1500" height="500" srcset="https://www.philisun.com/wp-content/uploads/2025/09/5跳线生产及检测环境.jpg 1500w, https://www.philisun.com/wp-content/uploads/2025/09/5跳线生产及检测环境-300x100.jpg 300w, https://www.philisun.com/wp-content/uploads/2025/09/5跳线生产及检测环境-1024x341.jpg 1024w, https://www.philisun.com/wp-content/uploads/2025/09/5跳线生产及检测环境-768x256.jpg 768w, https://www.philisun.com/wp-content/uploads/2025/09/5跳线生产及检测环境-500x167.jpg 500w, https://www.philisun.com/wp-content/uploads/2025/09/5跳线生产及检测环境-600x200.jpg 600w" sizes="auto, (max-width: 1500px) 100vw, 1500px" /></div>
<div></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">FIBER OPTIC CABLE STRUCTURE</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div><img loading="lazy" decoding="async" class="aligncenter wp-image-4252 size-full" src="https://www.philisun.com/wp-content/uploads/2026/01/光缆结构图-MPO-Trunks-6xBase-12.jpg" alt="" width="1300" height="336" srcset="https://www.philisun.com/wp-content/uploads/2026/01/光缆结构图-MPO-Trunks-6xBase-12.jpg 1300w, https://www.philisun.com/wp-content/uploads/2026/01/光缆结构图-MPO-Trunks-6xBase-12-300x78.jpg 300w, https://www.philisun.com/wp-content/uploads/2026/01/光缆结构图-MPO-Trunks-6xBase-12-1024x265.jpg 1024w, https://www.philisun.com/wp-content/uploads/2026/01/光缆结构图-MPO-Trunks-6xBase-12-768x198.jpg 768w, https://www.philisun.com/wp-content/uploads/2026/01/光缆结构图-MPO-Trunks-6xBase-12-500x129.jpg 500w, https://www.philisun.com/wp-content/uploads/2026/01/光缆结构图-MPO-Trunks-6xBase-12-600x155.jpg 600w" sizes="auto, (max-width: 1300px) 100vw, 1300px" /></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">PERFORMANCE PARAMETER</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div class="tablepress-wrapper">
<table id="tablepress-8-no-2" class="tablepress tablepress-id-8 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="4" class="column-1">Technical Performance</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2">
	<td rowspan="2" class="column-1">Ferrule type</td><td colspan="2" class="column-2">Insertion loss</td><td rowspan="2" class="column-4">Return loss</td>
</tr>
<tr class="row-3">
	<td class="column-2">Typical</td><td class="column-3">Maximum</td>
</tr>
<tr class="row-4">
	<td class="column-1">SM standard loss</td><td class="column-2">0.20dB</td><td class="column-3">≤0.75dB</td><td rowspan="2" class="column-4">≥ 60dB （APC 8°）</td>
</tr>
<tr class="row-5">
	<td class="column-1">SM low loss</td><td class="column-2">0.10dB</td><td class="column-3">≤0.35dB</td>
</tr>
<tr class="row-6">
	<td class="column-1">MM standard loss</td><td class="column-2">0.20dB</td><td class="column-3">≤0.6dB</td><td rowspan="2" class="column-4">≥ 20dB</td>
</tr>
<tr class="row-7">
	<td class="column-1">MM low loss</td><td class="column-2">0.10dB</td><td class="column-3">≤0.35dB</td>
</tr>
</tbody>
</table>
<!-- #tablepress-8-no-2 from cache --></div>
<div></div>
<div class="tablepress-wrapper">
<table id="tablepress-9-no-2" class="tablepress tablepress-id-9 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="7" class="column-1">MT Ferrule Options</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2">
	<td colspan="2" class="column-1">Fiber mode</td><td colspan="2" class="column-3">Performance</td><td colspan="3" class="column-5">Fiber count</td>
</tr>
<tr class="row-3">
	<td colspan="2" rowspan="3" class="column-1">Single mode</td><td colspan="2" rowspan="2" class="column-3">Standard loss</td><td colspan="3" class="column-5">12 (1x12)</td>
</tr>
<tr class="row-4">
	<td colspan="3" class="column-5">24 (2x12)</td>
</tr>
<tr class="row-5">
	<td colspan="2" class="column-3">Low loss</td><td colspan="3" class="column-5">12 (1x12)</td>
</tr>
<tr class="row-6">
	<td colspan="2" rowspan="6" class="column-1">Multimode</td><td colspan="2" rowspan="4" class="column-3">Standard loss</td><td colspan="3" class="column-5">12 (1x12)</td>
</tr>
<tr class="row-7">
	<td colspan="3" class="column-5">16 (1x16)</td>
</tr>
<tr class="row-8">
	<td colspan="3" class="column-5">24 (2x12)</td>
</tr>
<tr class="row-9">
	<td colspan="3" class="column-5">32 (2x16)</td>
</tr>
<tr class="row-10">
	<td colspan="2" rowspan="2" class="column-3">Low loss</td><td colspan="3" class="column-5">12 (1x12)</td>
</tr>
<tr class="row-11">
	<td colspan="3" class="column-5">24 (2x12)</td>
</tr>
</tbody>
</table>
<!-- #tablepress-9-no-2 from cache --></div>
<div></div>
<div class="tablepress-wrapper">
<table id="tablepress-125-no-2" class="tablepress tablepress-id-125 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="9" class="column-1">Cable Parameter</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2">
	<td colspan="2" class="column-1">Items</td><td colspan="7" class="column-3">Specifications</td>
</tr>
<tr class="row-3">
	<td colspan="2" class="column-1"> Fiber Count</td><td class="column-3">24</td><td class="column-4">32</td><td class="column-5">36</td><td class="column-6">48</td><td class="column-7">72</td><td class="column-8">96</td><td class="column-9">144</td>
</tr>
<tr class="row-4">
	<td colspan="2" class="column-1">Unit Count</td><td class="column-3">2 or 3</td><td class="column-4">2 or 4</td><td class="column-5">3</td><td class="column-6">4 or 6</td><td class="column-7">6</td><td class="column-8">8 or 12</td><td class="column-9">12 or 24</td>
</tr>
<tr class="row-5">
	<td colspan="2" class="column-1">Fillers</td><td class="column-3">2</td><td colspan="6" class="column-4">0</td>
</tr>
<tr class="row-6">
	<td rowspan="2" class="column-1">Fiber</td><td class="column-2">Diameter</td><td colspan="7" class="column-3">250±15μm</td>
</tr>
<tr class="row-7">
	<td class="column-2">Color</td><td colspan="7" class="column-3">Blue/Orange/Green/Brown/Gray/White/Red/Black/Yellow/Purple/Pink/Aqua</td>
</tr>
<tr class="row-8">
	<td rowspan="6" class="column-1">Subunit</td><td class="column-2"> Fiber Count</td><td colspan="7" class="column-3">12</td>
</tr>
<tr class="row-9">
	<td class="column-2">Diameter</td><td colspan="7" class="column-3">2.9±0.1mm</td>
</tr>
<tr class="row-10">
	<td class="column-2">Material</td><td colspan="7" class="column-3">PVC /LSZH</td>
</tr>
<tr class="row-11">
	<td class="column-2">Color<sup>1</sup></td><td colspan="7" class="column-3">Blue/Orange/Green/Brown/Gray/White/Red/Black/Yellow/Purple/Pink/Aqua</td>
</tr>
<tr class="row-12">
	<td class="column-2">Strength Member</td><td colspan="7" class="column-3">Aramid Yarn</td>
</tr>
<tr class="row-13">
	<td class="column-2">Marks<sup>1</sup></td><td colspan="7" class="column-3">1# - 12#</td>
</tr>
<tr class="row-14">
	<td colspan="2" class="column-1">Central Strength Member<sup>2</sup></td><td colspan="4" class="column-3">-</td><td colspan="3" class="column-7">FRP +(PVC / LSZH)</td>
</tr>
<tr class="row-15">
	<td rowspan="3" class="column-1">  Outer Jacket</td><td class="column-2">Diameter</td><td colspan="4" class="column-3">9.5±0.5mm</td><td class="column-7">11.5±0.5mm</td><td class="column-8">13.5±0.5mm</td><td class="column-9">17.0±0.5mm</td>
</tr>
<tr class="row-16">
	<td class="column-2">Material</td><td colspan="7" class="column-3">PVC /LSZH</td>
</tr>
<tr class="row-17">
	<td class="column-2">Color</td><td colspan="7" class="column-3">Blue/Orange/Green/Brown/Gray/White/Red/Black/Yellow/Purple/Pink/Aqua</td>
</tr>
<tr class="row-18">
	<td colspan="9" rowspan="3" class="column-1">Note 1: Each subunit is usually distinguished by different jacket colors, number marks only for optional.<br />
Note 2: The central strength member is optional for 48FO mini cable.<br />
Note 3: The fiber count in each subunit can be customized, equal or unequal.</td>
</tr>
<tr class="row-19">
	
</tr>
<tr class="row-20">
	
</tr>
</tbody>
</table>
<!-- #tablepress-125-no-2 from cache --></div>
<div></div>
<div class="tablepress-wrapper">
<table id="tablepress-126-no-2" class="tablepress tablepress-id-126 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="8" class="column-1">Mechanical Performance</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2">
	<td class="column-1">Items</td><td colspan="7" class="column-2">Specifications</td>
</tr>
<tr class="row-3">
	<td class="column-1">Fiber Count</td><td class="column-2">24</td><td class="column-3">32</td><td class="column-4">36</td><td class="column-5">48</td><td class="column-6">72</td><td class="column-7">96</td><td class="column-8">144</td>
</tr>
<tr class="row-4">
	<td class="column-1">Subunit Count</td><td class="column-2">2 or 3</td><td class="column-3">2 or 4</td><td class="column-4">3</td><td class="column-5">4 or 6</td><td class="column-6">6</td><td class="column-7">8 or 12</td><td class="column-8">12 or 24</td>
</tr>
<tr class="row-5">
	<td class="column-1">Tensile Strength (Long Term) / N</td><td colspan="3" class="column-2">300</td><td class="column-5">200</td><td colspan="3" class="column-6">400</td>
</tr>
<tr class="row-6">
	<td class="column-1">Tensile Strength (Short Term)/ N</td><td colspan="3" class="column-2">600</td><td class="column-5">400</td><td colspan="3" class="column-6">1000</td>
</tr>
<tr class="row-7">
	<td class="column-1">Crush Resistance<br />
 (Long Term) / N/10cm</td><td colspan="7" class="column-2">300</td>
</tr>
<tr class="row-8">
	<td class="column-1">Crush Resistance<br />
 (Long Term) / N/10cm</td><td colspan="7" class="column-2">1000</td>
</tr>
<tr class="row-9">
	<td class="column-1"> Min. Bend Radius (Dynamic) / mm</td><td colspan="7" class="column-2">20D</td>
</tr>
<tr class="row-10">
	<td class="column-1">Min. Bend Radius (Static)/ mm</td><td colspan="7" class="column-2">10D</td>
</tr>
<tr class="row-11">
	<td class="column-1">Operating Temperature/℃</td><td colspan="7" class="column-2">-20～+60</td>
</tr>
<tr class="row-12">
	<td class="column-1">Storage Temperature/℃</td><td colspan="7" class="column-2">-20～+60</td>
</tr>
</tbody>
</table>
<!-- #tablepress-126-no-2 from cache --></div>
<div></div>
<div class="tablepress-wrapper">
<table id="tablepress-7-no-2" class="tablepress tablepress-id-7 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="9" class="column-1">SM Fiber Parameter</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2">
	<td colspan="5" class="column-1">Items</td><td class="column-6">Unit</td><td class="column-7">G.652D</td><td class="column-8">G.657A1</td><td class="column-9">G.657A2</td>
</tr>
<tr class="row-3">
	<td colspan="3" rowspan="2" class="column-1">Mode Field Diameter</td><td colspan="2" class="column-4">1310nm</td><td class="column-6">μm</td><td class="column-7">9.1±0.4</td><td class="column-8">8.8±0.4</td><td class="column-9">8.8±0.4</td>
</tr>
<tr class="row-4">
	<td colspan="2" class="column-4">1550nm</td><td class="column-6">μm</td><td class="column-7">10.4±0.5</td><td class="column-8">9.8±0.5</td><td class="column-9">9.8±0.5</td>
</tr>
<tr class="row-5">
	<td colspan="5" class="column-1">Cladding Diameter</td><td class="column-6">μm</td><td class="column-7">125±1</td><td class="column-8">125±0.7</td><td class="column-9">125±0.7</td>
</tr>
<tr class="row-6">
	<td colspan="5" class="column-1">Cladding Non-Circularity</td><td class="column-6">%</td><td class="column-7">≤1</td><td class="column-8">≤0.7</td><td class="column-9">≤0.7</td>
</tr>
<tr class="row-7">
	<td colspan="5" class="column-1">Core-Cladding Concentricity Error</td><td class="column-6">μm</td><td class="column-7">≤0.6</td><td class="column-8">≤0.5</td><td class="column-9">≤0.5</td>
</tr>
<tr class="row-8">
	<td colspan="5" class="column-1">Coating Diameter</td><td class="column-6">μm</td><td class="column-7">245±7</td><td class="column-8">245±5</td><td class="column-9">245±5</td>
</tr>
<tr class="row-9">
	<td colspan="5" class="column-1">Coating Non-Circularity</td><td class="column-6">%</td><td class="column-7">≤6.0</td><td class="column-8">≤6.0</td><td class="column-9">≤6.0</td>
</tr>
<tr class="row-10">
	<td colspan="5" class="column-1">Cladding-Coating Concentricity Error</td><td class="column-6">μm</td><td class="column-7">≤12.0</td><td class="column-8">≤12.0</td><td class="column-9">≤12.0</td>
</tr>
<tr class="row-11">
	<td colspan="5" class="column-1">Cable Cutoff Wavelength</td><td class="column-6">nm</td><td class="column-7">λcc≤1260</td><td class="column-8">λcc≤1260</td><td class="column-9">λcc≤1260</td>
</tr>
<tr class="row-12">
	<td colspan="3" rowspan="2" class="column-1">Cable Attenuation Coefficient</td><td colspan="2" class="column-4">1310nm</td><td class="column-6">dB/km</td><td class="column-7">≤0.4</td><td class="column-8">≤0.4</td><td class="column-9">≤0.4</td>
</tr>
<tr class="row-13">
	<td colspan="2" class="column-4">1550nm</td><td class="column-6">dB/km</td><td class="column-7">≤0.3</td><td class="column-8">≤0.3</td><td class="column-9">≤0.3</td>
</tr>
</tbody>
</table>
<!-- #tablepress-7-no-2 from cache --></div>
<div></div>
<div class="tablepress-wrapper">
<table id="tablepress-19-no-2" class="tablepress tablepress-id-19 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="9" class="column-1">MM Fiber Parameter</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2">
	<td colspan="3" class="column-1">Items</td><td class="column-4">unit</td><td class="column-5">62.5/125</td><td class="column-6">50/125</td><td class="column-7">OM3-150</td><td class="column-8">OM3-300</td><td class="column-9">OM4</td>
</tr>
<tr class="row-3">
	<td colspan="3" class="column-1">Core Diameter</td><td class="column-4">μm</td><td class="column-5">62.5±2.5</td><td class="column-6">50±2.5</td><td class="column-7">50±2.5</td><td class="column-8">50±2.5</td><td class="column-9">50±2.5</td>
</tr>
<tr class="row-4">
	<td colspan="3" class="column-1">Cladding Diameter</td><td class="column-4">μm</td><td class="column-5">125±1.0</td><td class="column-6">125±1.0</td><td class="column-7">125±1.0</td><td class="column-8">125±1.0</td><td class="column-9">125±1.0</td>
</tr>
<tr class="row-5">
	<td colspan="3" class="column-1">Core Non-Circularity</td><td class="column-4">%</td><td class="column-5">≤5.0</td><td class="column-6">≤5.0</td><td class="column-7">≤5.0</td><td class="column-8">≤5.0</td><td class="column-9">≤5.0</td>
</tr>
<tr class="row-6">
	<td colspan="3" class="column-1">Cladding Non-Circularity</td><td class="column-4">%</td><td class="column-5">≤1.0</td><td class="column-6">≤1.0</td><td class="column-7">≤1.0</td><td class="column-8">≤1.0</td><td class="column-9">≤1.0</td>
</tr>
<tr class="row-7">
	<td colspan="3" class="column-1">Core-Cladding Concentricity Error</td><td class="column-4">μm</td><td class="column-5">≤1.5</td><td class="column-6">≤1.5</td><td class="column-7">≤1.0</td><td class="column-8">≤1.0</td><td class="column-9">≤1.0</td>
</tr>
<tr class="row-8">
	<td colspan="3" class="column-1">Coating Diameter</td><td class="column-4">μm</td><td class="column-5">245±7</td><td class="column-6">245±7</td><td class="column-7">245±7</td><td class="column-8">245±7</td><td class="column-9">245±7</td>
</tr>
<tr class="row-9">
	<td colspan="3" class="column-1">Coating Non-Circularity</td><td class="column-4">%</td><td class="column-5">≤6.0</td><td class="column-6">≤6.0</td><td class="column-7">≤6.0</td><td class="column-8">≤6.0</td><td class="column-9">≤6.0</td>
</tr>
<tr class="row-10">
	<td colspan="3" class="column-1">Cladding-Coating Concentricity Error</td><td class="column-4">μm</td><td class="column-5">≤12.0</td><td class="column-6">≤12.0</td><td class="column-7">≤12.0</td><td class="column-8">≤12.0</td><td class="column-9">≤12.0</td>
</tr>
<tr class="row-11">
	<td colspan="2" rowspan="2" class="column-1">OFL Bandwidth</td><td class="column-3">850nm</td><td class="column-4">MHz·km</td><td class="column-5">≥160</td><td class="column-6">≥500</td><td class="column-7">≥700</td><td class="column-8">≥1500</td><td class="column-9">≥3500</td>
</tr>
<tr class="row-12">
	<td class="column-3">1300nm</td><td class="column-4">MHz·km</td><td class="column-5">≥500</td><td class="column-6">≥500</td><td class="column-7">≥500</td><td class="column-8">≥500</td><td class="column-9">≥500</td>
</tr>
<tr class="row-13">
	<td colspan="2" rowspan="2" class="column-1">Cable Attenuation Coefficient</td><td class="column-3">850nm</td><td class="column-4">dB/km</td><td class="column-5">≤3.0</td><td class="column-6">≤3.0</td><td class="column-7">≤3.0</td><td class="column-8">≤3.0</td><td class="column-9">≤3.0</td>
</tr>
<tr class="row-14">
	<td class="column-3">1300nm</td><td class="column-4">dB/km</td><td class="column-5">≤1.0</td><td class="column-6">≤1.0</td><td class="column-7">≤1.0</td><td class="column-8">≤1.0</td><td class="column-9">≤1.0</td>
</tr>
</tbody>
</table>
<!-- #tablepress-19-no-2 from cache --></div>
<div></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">Product Certification</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-2079" src="https://www.philisun.com/wp-content/uploads/2025/09/认证模块-跳线.jpg" alt="" width="1240" height="326" srcset="https://www.philisun.com/wp-content/uploads/2025/09/认证模块-跳线.jpg 1240w, https://www.philisun.com/wp-content/uploads/2025/09/认证模块-跳线-300x79.jpg 300w, https://www.philisun.com/wp-content/uploads/2025/09/认证模块-跳线-1024x269.jpg 1024w, https://www.philisun.com/wp-content/uploads/2025/09/认证模块-跳线-768x202.jpg 768w, https://www.philisun.com/wp-content/uploads/2025/09/认证模块-跳线-500x131.jpg 500w, https://www.philisun.com/wp-content/uploads/2025/09/认证模块-跳线-600x158.jpg 600w" sizes="auto, (max-width: 1240px) 100vw, 1240px" /></div>
<div></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">Quality Advantage</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-2080" src="https://www.philisun.com/wp-content/uploads/2025/09/品质对比-跳线.jpg" alt="" width="1350" height="1300" srcset="https://www.philisun.com/wp-content/uploads/2025/09/品质对比-跳线.jpg 1350w, https://www.philisun.com/wp-content/uploads/2025/09/品质对比-跳线-300x289.jpg 300w, https://www.philisun.com/wp-content/uploads/2025/09/品质对比-跳线-1024x986.jpg 1024w, https://www.philisun.com/wp-content/uploads/2025/09/品质对比-跳线-768x740.jpg 768w, https://www.philisun.com/wp-content/uploads/2025/09/品质对比-跳线-500x481.jpg 500w, https://www.philisun.com/wp-content/uploads/2025/09/品质对比-跳线-600x578.jpg 600w" sizes="auto, (max-width: 1350px) 100vw, 1350px" /></div>
<div></div>
<p>&nbsp;</p>
<div></div>
<div class="prod-test-title-container">
<div class="title-line left-line"></div>
<div class="title-dot left-dot"></div>
<div class="title-text">CONFIGURATION INFORMATION</div>
<div class="title-dot right-dot"></div>
<div class="title-line right-line"></div>
</div>
<div></div>
<div>The form can be filled in the actual <a href="https://www.philisun.com/products/mpo-144-fibers-base-12-trunk-cable/">website url</a>.</div>
<div></div>
<div></div>
<div></div>
<div></div>
<p><a rel="nofollow" href="https://www.philisun.com/products/mpo-144-fibers-base-12-trunk-cable/">MPO-144 Trunk Cable &#8211; 144 Fiber Main Trunk Cord, Base-12, Supports OS2/OM3/OM4/OM5, for Maximum Density Backbone, PC/APC Polish (Female/Male), Type A/B/C</a>最先出现在<a rel="nofollow" href="https://www.philisun.com">www.philisun.com</a>。</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
